A vanadium half-cell in two dimensions, with flow#

This demo extends A vanadium half-cell in one dimension with the flow of the electrolyte through the porous electrode, as the 2D example of RFBniCS [1]. It shows how to:

  • Solve Darcy flow through the electrode with Darcy, and check it against its exact solution

  • Couple the half-cell to the flow, which carries the ions in at the inlet and out at the outlet, and limits the kinetics by mass transfer to the fibres

  • Name the dimensionless numbers of the flow from the expressions of the model

  • Run the half-cell through a charging and discharging schedule, and plot its local state of charge

The model#

The electrode spans the width \(W\) from the current collector at \(x = 0\) to the membrane at \(x = W\), and the height \(H\) from the inlet at \(y = 0\) to the outlet at \(y = H\). The electrolyte enters at the inlet with the superficial velocity \(v_{\text{in}}\) and leaves at the outlet, held at the pressure \(p_{\text{out}}\). In the pores, Darcy’s law gives the superficial velocity \(\mathbf{u}\) from the pressure \(p\), with the permeability \(K\) of the electrode and the viscosity \(\mu\) of the electrolyte:

(39)#\[\begin{split} \begin{aligned} \mathbf{u} &= -\frac{K}{\mu} \nabla p, \\ \nabla \cdot \mathbf{u} &= 0, \\ -\mathbf{u} \cdot \mathbf{n} &= v_{\text{in}} \quad \text{at the inlet}, \\ p &= p_{\text{out}} \quad \text{at the outlet}, \end{aligned} \end{split}\]

and no flow through the other sides. Darcy’s law is the balance of the pressure gradient and the Darcy drag in the volume-averaged Navier-Stokes equations, whose inertia, viscous diffusion and Forchheimer drag are negligible in the electrode [1] (Section II B 5). The permeability follows from the porosity and the fibre diameter by the Kozeny-Carman relation, see kozeny_carman.

The half-cell is that of (35) in A vanadium half-cell in one dimension, with three changes. The Nernst-Planck fluxes carry the ions with \(\mathbf{u}\). The concentrations of the reservoir hold at the inlet instead of the membrane, the ions leave with the flow at the outlet, and the membrane passes the current of the cell as protons. The reaction takes the concentrations at the surface of the fibres, which mass transfer from the pores, at the rate \(k_m (c - c_s)\), ties to the concentrations \(c\) of the pores, with a mass-transfer coefficient \(k_m\) from the correlation of [2], see MassTransferButlerVolmer. These are the boundary conditions and kinetics of [1] (Sections II B 4 and II C). The flow is steady and does not depend on the electrochemistry, so it is solved once, first.

We import the relevant packages:

Hide code cell source

from mpi4py import MPI

import dolfinx.fem
import dolfinx.mesh
import matplotlib.pyplot as plt
import numpy as np
import pyvista
import sympy.physics.units as syu
import ufl

from sumfem import discrete, solvers, symbolic
from sumfem.electrochemistry import Ion, PorousElectrode, RedoxCouple, RedoxHalfCell
from sumfem.models import BoundaryFlux, Darcy
from sumfem.plotting import gather_grid

The electrode#

The cell is a rectangle of quadrilaterals, with its sides marked. They are located with a tolerance relative to the height, see A domain and its length scale:

width, height, cells = 2.5e-3, 1e-2, (25, 100)
dtype = dolfinx.default_real_type
rectangle = dolfinx.mesh.create_rectangle(
    MPI.COMM_WORLD,
    np.array([[0.0, 0.0], [width, height]]),
    list(cells),
    cell_type=dolfinx.mesh.CellType.quadrilateral,
    dtype=dtype,
)
tolerance = 100 * float(np.finfo(dtype).eps) * height
marked = discrete.MeshData.from_locators(
    rectangle,
    {
        1: {
            "CurrentCollector": lambda x: np.isclose(x[0], 0.0, atol=tolerance),
            "Membrane": lambda x: np.isclose(x[0], width, atol=tolerance),
            "Inlet": lambda x: np.isclose(x[1], 0.0, atol=tolerance),
            "Outlet": lambda x: np.isclose(x[1], height, atol=tolerance),
        }
    },
    boundary=True,
)
domain = symbolic.Domain.from_mesh("cell", rectangle, length_scale=width)

The porous electrode is the carbon felt of A vanadium half-cell in one dimension, whose fibres of several micrometres [3] now matter: their diameter sets the permeability and the mass transfer. RFBniCS [1] uses a diameter far below that range, kept in a comment:

electrode = PorousElectrode(
    "electrode",
    domain,
    porosity=0.94,
    conductivity=3402.1 * syu.siemens / syu.m,
    specific_area=2.3e4 / syu.m,
    fiber_diameter=8.0 * syu.micrometer,  # RFBniCS: 0.5 micrometre
    kozeny_carman_constant=5.55,
    pore_length=100.0 * syu.micrometer,
)

The flow#

The density and the viscosity of the electrolyte are parameters that the flow and the half-cell share, as are the inlet velocity and the outlet pressure. The flow depends on the gradient of the pressure alone, so the pressure is the gauge pressure, zero at the outlet: an offset as large as the atmospheric pressure would cost the small pressure drop its digits.

viscosity = symbolic.Parameter(
    "electrolyte.viscosity",
    domain,
    default=6.963e-3 * syu.pascal * syu.second,
    unit=syu.pascal * syu.second,
    doc="Dynamic viscosity of the electrolyte",
)
density = symbolic.Parameter(
    "electrolyte.density",
    domain,
    default=1399.8 * syu.kg / syu.m**3,
    unit=syu.kg / syu.m**3,
    doc="Density of the electrolyte",
)
inlet_velocity = symbolic.Parameter(
    "flow.inlet_velocity",
    domain,
    default=1e-7 * syu.m / syu.second,
    unit=syu.m / syu.second,
    doc="Superficial velocity at the inlet",
)
outlet_pressure = symbolic.Parameter(
    "flow.outlet_pressure",
    domain,
    default=0.0 * syu.pascal,
    unit=syu.pascal,
    doc="Gauge pressure at the outlet",
)

The pressure drop \(\mu v_{\text{in}} H / K\) of the uniform flow through the electrode is the scale of the pressure. value_at_defaults evaluates it, an expression of parameters, at their defaults:

pressure_drop = symbolic.value_at_defaults(
    viscosity * inlet_velocity * height / electrode.permeability()
)
p = symbolic.Field("p", domain, ("Lagrange", 1), unit=syu.pascal, scale=pressure_drop)

Darcy is the flow of (39), and a BoundaryFlux its inflow. Its system is checked for units and solved in dimensionless form, see Scaling the equations:

darcy = Darcy("darcy", p, electrode.permeability(), viscosity)
flow = darcy + BoundaryFlux("inflow", p, inlet_velocity, ("Inlet",))
flow_system = symbolic.build_system(flow, check_units=True, factorize_equations=True)
outlet = symbolic.DirichletBC(p, "Outlet", outlet_pressure)

The half-cell#

The ions and the reservoir are those of A vanadium half-cell in one dimension, with sulfate from electroneutrality:

diffusivity = syu.m**2 / syu.second
concentration = syu.mol / syu.m**3
ions = (
    Ion("V2", 2, 8.10e-12 * diffusivity),
    Ion("V3", 3, 1.65e-11 * diffusivity),
    Ion("H", 1, 9.312e-9 * diffusivity),
    Ion("HSO4", -1, 1.33e-9 * diffusivity),
    Ion("SO4", -2, 1.065e-9 * diffusivity),
)
reservoir = {
    "V2": 300.0 * concentration,
    "V3": 300.0 * concentration,
    "H": 1000.0 * concentration,
    "HSO4": 1000.0 * concentration,
}

The half-cell is the negative one of A vanadium half-cell in one dimension, with its couple. The superficial velocity of the flow carries the ions and drives the mass transfer to the fibres, which a velocity switches on. The flow carries the ions out at the outlet, the membrane passes the current as protons with proton_flux, and the reservoir concentrations hold at the inlet:

couple = RedoxCouple(
    reduced="V2",
    oxidized="V3",
    rate_constant=2.5e-7 * syu.m / syu.second,
    formal_potential=-0.36 * syu.volt,
    oxidation_on_discharge=True,
)
cell = RedoxHalfCell(
    domain,
    ions,
    reservoir,
    couple,
    electrode,
    velocity=darcy.superficial_velocity,
    outlet=("Outlet",),
    proton_flux=True,
    density=density,
    viscosity=viscosity,
)
inlet = cell.inlet_conditions("Inlet")

The flow and the half-cell are discretized together, so they share their parameters, with the quadrature degree of the nonlinear kinetics bounded as in A vanadium half-cell in one dimension. A Solver solves the flow:

disc = discrete.discretize(
    [flow_system, outlet, cell.model, *inlet],
    discrete.DomainMaps({domain: marked}),
    max_quadrature_degree=4,
)
solvers.Solver(disc[flow_system], [outlet]).solve()
(Coefficient(FunctionSpace(Mesh(blocked element (Basix element (P, quadrilateral, 1, gll_warped, unset, False, float64, []), (2,)), 0), Basix element (P, quadrilateral, 1, gll_warped, unset, False, float64, [])), 43),)

With a uniform permeability, the flow is uniform, and the pressure falls linearly from the inlet to the outlet by \(\mu v_{\text{in}} H / K\). Linear elements hold it exactly, so the pressure drop and the outflow, the flux of the superficial velocity through the outlet, match it to round-off:

n = ufl.FacetNormal(domain)
ds_inlet, ds_outlet = domain.ds("Inlet"), domain.ds("Outlet")
area = disc.assemble_scalar(1.0 * domain.dx())
v_in = float(disc.value(inlet_velocity))
drop = disc.assemble_scalar((p - outlet_pressure) * ds_inlet) / width
outflow = disc.assemble_scalar(ufl.dot(darcy.superficial_velocity, n) * ds_outlet)
print(f"Pressure drop: {drop:.6g} Pa, exact {pressure_drop:.6g} Pa")
print(f"Outflow over inflow: {outflow / (v_in * width):.12f}")
assert np.isclose(drop, pressure_drop, rtol=1e-8)
assert np.isclose(outflow, v_in * width, rtol=1e-8)
Pressure drop: 0.00261715 Pa, exact 0.00261715 Pa
Outflow over inflow: 1.000000000001

Dimensionless numbers of the flow#

The flow past the fibres has the Reynolds number \(\rho |\mathbf{u}| d / \mu\) of the fibre diameter \(d\), which the kinetics compute, and sets the Sherwood number \(k_m d / D\) of the mass transfer by the correlation of MassTransferButlerVolmer. Along the electrode, the mass Péclet number \(v_{\text{in}} H / D\) of V²⁺ compares the transport by the flow with diffusion. Their means over the electrode:

reaction = cell.reaction
reynolds = disc.assemble_scalar(reaction.reynolds_number() * domain.dx()) / area
d_V2 = float(disc.value(cell.electrolyte.diffusivity("V2")))
d_fibre = float(disc.value(electrode.fiber_diameter))
(k_V2, _) = reaction.mass_transfer_coefficients()
sherwood = disc.assemble_scalar(k_V2 * domain.dx()) / area * d_fibre / d_V2
peclet = v_in * height / d_V2
print(f"Reynolds number of the fibres: {reynolds:.3g}")
print(f"Sherwood number of V2+: {sherwood:.3g}")
print(f"Mass Peclet number of V2+ along the electrode: {peclet:.3g}")
assert reynolds < 1 and peclet > 1
Reynolds number of the fibres: 1.61e-07
Sherwood number of V2+: 0.0134
Mass Peclet number of V2+ along the electrode: 123

The flow is creeping, so Darcy’s law holds, yet it carries the ions along the electrode faster than they diffuse.

Charge, rest and discharge#

The schedule of A vanadium half-cell in one dimension, run by a Simulation in parts, one for each current and step size. The simulation’s model is the half-cell alone: the flow does not depend on the electrochemistry and its inputs are fixed, so every step takes the pressure solved above as known, and the velocity from it, without solving the flow again. The initial state is at rest, and the reference time of the time derivatives is the largest step:

schedule = (
    ("charge", 0.5, ((20, 0.1), (10, 1.0), (10, 10.0))),
    ("rest", 0.0, ((5, 0.1), (5, 1.0), (10, 10.0))),
    ("discharge", 0.5, ((20, 0.1), (10, 1.0), (10, 10.0))),
)
sign = {"charge": -1.0, "rest": 0.0, "discharge": 1.0}
largest_step = max(dt for *_, steps in schedule for _, dt in steps)
cell.initialize(disc)
clock = symbolic.Clock(domain, dt=schedule[0][2][0][1])
simulation = solvers.Simulation(
    disc,
    cell.model,
    inlet,
    clock=clock,
    scheme=solvers.BDF(1),
    petsc_options={"snes_linesearch_type": "bt", "snes_max_it": 100},
    check_units=True,
    factorize_equations=True,
    time_scale=largest_step,
)

After every step, a callback records the time, the mode, the voltage and the state of charge. At the end of the charge, the local state of charge, the share of V²⁺ in the vanadium at each point, is kept for a plot:

local = cell.local_state_of_charge()
space = disc.function_space(cell.concentrations["V2"])
charged = dolfinx.fem.Function(space, name="soc")
records: list[tuple[float, str, float, float]] = []
for mode, current, steps in schedule:
    disc.set({cell.current: sign[mode] * current})
    for count, dt in steps:
        disc.set({clock.dt: dt})
        simulation.run(
            num_steps=count,
            callback=lambda t, step, mode=mode: records.append(
                (t, mode, cell.voltage(disc), cell.state_of_charge(disc))
            ),
        )
    if mode == "charge":
        charged.interpolate(
            dolfinx.fem.Expression(disc[local], space.element.interpolation_points)
        )
times = np.array([r[0] for r in records])
modes = np.array([r[1] for r in records])
voltage = np.array([r[2] for r in records])
charge = np.array([r[3] for r in records])

Charging raises the state of charge and discharging lowers it. The flow now renews the electrolyte, so at rest it carries the charged electrolyte out and brings the reservoir’s in: the state of charge falls back towards that of the reservoir. Sulfate, which follows from electroneutrality, stays positive, see minimum_balanced_concentration:

steps = {mode: np.diff(charge[modes == mode]) for mode in ("charge", "discharge")}
rest = charge[modes == "rest"]
print(f"State of charge after charge: {charge[modes == 'charge'][-1]:.6f}")
print(f"State of charge after rest: {rest[-1]:.6f}")
print(f"State of charge at the end: {charge[-1]:.6f}")
assert np.all(steps["charge"] > 0) and np.all(steps["discharge"] < 0)
assert np.all(np.diff(rest) < 0)
assert voltage[modes == "charge"].mean() < voltage[modes == "discharge"].mean()
assert np.isfinite(voltage).all()
assert cell.minimum_balanced_concentration(disc) > 0
State of charge after charge: 0.500410
State of charge after rest: 0.500409
State of charge at the end: 0.499998

The voltage and the state of charge through the schedule:

fig, (top, bottom) = plt.subplots(2, 1, sharex=True)
for mode in ("charge", "rest", "discharge"):
    top.plot(times[modes == mode], 1e3 * voltage[modes == mode], ".", label=mode)
    bottom.plot(times[modes == mode], charge[modes == mode], ".", label=mode)
top.set_ylabel("Voltage (mV)")
bottom.set_ylabel("State of charge")
bottom.set_xlabel("Time (s)")
top.legend()
plt.show()
../../_images/b85a417cdef353282c3abb749bfcd8073a0358bb52fae1e6fb29b167de046cf2.png

The local state of charge at the end of the charge, gathered from all processes with gather_grid. The electrode is drawn in millimetres, widened to show its width:

grid = gather_grid(charged)
if MPI.COMM_WORLD.rank == 0:
    grid.points[:, 0] *= 4e3
    grid.points[:, 1] *= 1e3
    plotter = pyvista.Plotter(window_size=[480, 640])
    plotter.add_mesh(grid, scalars="soc", scalar_bar_args={"title": "SOC"})
    plotter.view_xy()
    plotter.show()

References#